Aico Ei Ei168RC Guide d'installation

Naviguer en ligne ou télécharger Guide d'installation pour Détecteurs de fumée Aico Ei Ei168RC. Aico Ei Ei168RC Installation guide [en] [fr] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
IDEALLY INSTALL IN THE CENTRE OF CEILING
AT LEAST 300mm FROM LIGHT FITTINGS
LOCATE IONISATION ALARMS AWAY FROM
KITCHENS TO PREVENT NUISANCE ALARMS
ENSURE LIVE MAINS IS CORRECTLY
CONNECTED TO L TERMINALS ON ALL
INTERCONNECTED ALARMS - OTHERWISE
UNITS WILL BE DAMAGED
DO NOT FIT ACTUAL ALARM UNTIL ALL
BUILDING WORK IS COMPLETED TO AVOID
CONTAMINATION. AFTER CHECKING
OPERATION, COVER SMOKE ALARM WITH
DUST COVER UNTIL REQUIRED FOR USE
DISCONNECT THE ALARM BEFORE APPLYING
HIGH VOLTAGE INSULATION TESTS TO WIRING
DO NOT ATTEMPT TO OPEN THE ALARM AS
IT IS PERMANENTLY SEALED FOR SAFETY
DO NOT CONNECT ALTERNATIVE ENERGY
SOURCES e.g. WIND, SOLAR, UPS WITH
NON-SINUSOIDAL OUTPUTS
(see INSTALLATION section)
INTERCONNECT ALL ALARMS
230V~ SMOKE & HEAT ALARMS
INSTALLER INSTRUCTIONS
RECHARGEABLE LITHIUM CELL BACK-UP
Ei161RC - Ionisation Ei166RC - OpticalEi164RC - Heat
Ei141RC - IonisationEi146RC - OpticalEi144RC - Heat
ALKALINE BATTERY BACK-UP
© Ei Electronics 2013P/N B17683 Rev0
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - INSTALLER INSTRUCTIONS

IDEALLY INSTALL IN THE CENTRE OF CEILINGAT LEAST 300mm FROM LIGHT FITTINGSLOCATE IONISATION ALARMS AWAY FROMKITCHENS TO PREVENT NUISANCE ALARMSENSURE

Page 2 - 1.1 Installation Guide

Wall mounting of smoke alarms (only):If ceiling mounting is impractical, smoke alarms may be mounted on a wall, provided that: a) the top of the detec

Page 3 - 2. Alarm Removal

• Do not locate in insect infested areas. Small insects getting into the smoke detector chamber can cause intermittent alarms. Insects and cont

Page 4 - 2. HOW MANY ALARMS TO INSTALL

Note: BS 5839-6 2004 gives the folowing recommendations regarding the mains supply to be used in a Grade D system (The Ei141RC/146RC/161RC

Page 5 - ADDITIONAL PROTECTION

We strongly recommend that you check for the following before connecting the alarm:• check for Live and Neutral using a two probe tester. • check for

Page 6

prevent air draughts affecting the smoke/heat entering the alarm. If the hole is too large or the alarm does not seal it, it should be sealed with sil

Page 7

In the UK it is recommended that the following coloured cores are used (for example with triple flat 6243Y cable).230V supply BrownNeutral

Page 8 - Locations & Performance

5. ACCESSORIESAlarm System Control Switch Ei1529RC:The System Control Switch is recommended for systems with three or more Smoke / Heat Alarms. It all

Page 9 - 3. POSITIONING ALARMS

1.1 Installation Guide2

Page 10 - 3.1 Locations To Avoid

2. Alarm RemovalSLIDE ALARM OFF BASE WITH THE SCREWDRIVER STILL INSERTED, PUSH THE LOWER HALF OF THE ALARM AWA

Page 11 - 4. INSTALLATION

2. HOW MANY ALARMS TO INSTALL- CATEGORIES & GRADES -The advice here follows the guidance in British Standard BS 5839-Part 6: 2004 in general (for

Page 12 - Figure 3

for dwellings where occupants may be at high risk (e.g. elderly)OPTIMUM PROTECTIONLD1Optimum Protection LD1: As LD2, but in additionSmoke or Heat Ala

Page 13 - Figure 5

for dwellings where occupants may be at high risk (e.g. elderly)OPTIMUM PROTECTIONLD1Optimum Protection LD1: As LD2, but in additionSmoke or Heat Ala

Page 14 - 4.2 Interconnecting Alarms

for dwellings where occupants may be at high risk (e.g. elderly)OPTIMUM PROTECTIONLD1Optimum Protection LD1: As LD2, but in additionSmoke or Heat Ala

Page 15 - Figure 6

2.2 Selecting Alarm Type1 Optical Smoke Alarms are recommended due to their excellent response to smouldering fires. If there is likely to be problems

Page 16 - 5. ACCESSORIES

Improved AudibilityThe effectiveness of Category LD2 and LD3 systems can be significantly enhanced if an additional Smoke Alarm (interconnecte

Commentaires sur ces manuels